- COROFLAKE Trowelled lining
COROFLAKE lining systems are applied with a trowel and protect metallic components against aggressive media under immersion conditions. They are based on polyester and vinylester resins and reinforced with micro-thin C-glass flakes. Whereas the chosen resin ensures excellent chemical resistance, the parallel alignment of the glass flakes to the underlying surface provides outstanding permeation resistance. A nominal thickness of 2.0 mm is achieved with just two layers. These COROFLAKE trowel lining systems can be used for wide media range at temperatures up to 90° C under immersion conditions. |
 |
|
 |
- COROFLAKE Spray coatings
Sprayed-on or rolled-on COROFLAKE systems combine the chemical resistance of trowel lining with the simplicity of the spray application technique. They are based on vinyl ester, epoxy and epoxy Novolac resins and reinforced with either C-glass flakes, mica or graphite. More than 100 flakes are applied on top of each other in a layer of 1 mm thickness. According to the environment, the lining will be applied in two or more layers at 1 to 2 mm thickness. COROFLAKE spray coatings offer economical long-term protection of installations and a long service life. They can be used at temperatures of up to 230° C under dry service conditions. |
|
Product |
Polymer |
Application / Properties |
Product-
information |
|
|
Novolac vinyl ester resin |
Suitable for separators, condensate collectors and FGD absorbers. |
|
|
|
Novolac vinyl ester resin |
Suitable for stacks, raw gas and bypass ducts as well as heat exchangers.
DIBt approval Z-59.13-283 |
|
|
|
|
Suitable for FGD raw gas and bypass ducts and for concrete protection. |
|
|
|
Novolac vinyl ester resin |
Suitable for flue gas ducts in FGD, also when having frequent temperature changes like in mixing chambers and heat exchangers. |
|
|
|
Bisphenol A vinyl ester resin |
Suitable for FGD raw gas and bypass ducts and wastewater containers. |
|
|
|
Special vinyl ester resin |
Suitable for FGD raw gas and bypass ducts as well as chimneys. |
|
|
|
|
Suitable for almost all installations in the petrochemical industry. |
|
|
|
|
Suitable for drinking water and for use in the food industry. KTW / DVWG W 270 approved. |
|
|
|
|